Diabetes
Other Therapy Areas
Explore diabetes
Explore obesity
Explore growth-related disorders
Explore rare bleeding disorders
Explore rare renal disorders
Explore hormone replacement therapy
Medical Information | Non-US Health Care Professionals
Account Settings
Sign Out
Sign In | Create Account
  • Diabetes Home
    • Products
      Diabetes Treatments
    • Professional Resources
      Product Resources Library Insulin & Type 1 Diabetes
  • Sample Requests
    • Diabetes Education
      Clinical Education Library Diabetes Risk Assessment Tool
    • Treatment Guidelines
      ADA Standards of Care AACE Diabetes Guidelines
    • Additional Resources
      Organizations & Conferences
    • Product Education
      Product Education Materials
    • Disease Education
      Disease Education Library
    • Prescription Savings & Coverage
      Savings Cards Insurance Coverage Affordability Resources ICD-10 Codes for Diabetes
    • Support Program
      Diabetes Management
  • Sign In
    Create Account
    • Account Settings
    • Sign Out
    Other Therapy Areas
    Medical Information
    Non-US Health Care Professionals
Fiasp® (insulin aspart) injection 100 U/mL logo
Important Safety Information | Patient Site
Prescribing Information
    • Flexible Dosing Options
    • Onset of Appearance
    • Fiasp® and Type 1 Diabetes
    • Frequently Asked Questions
    • Adult Efficacy and Safety
    • Pediatric Efficacy and Safety
    • Fiasp® Dosing
    • Administration Options
  • Pump Therapy
  • Cost and Coverage
    • Patient Support
    • For Pharmacists
    • Video Library
Fiasp® (insulin aspart) injection 100 U/mL logo

Prescribing Information
Important Safety Information | Patient Site

For your patients with diabetes who struggle with pre-bolusing mealtime insulin

Choose Fiasp®


Fiasp® is a rapid-acting insulin indicated to improve glycemic control in adult and pediatric patients with diabetes.1

For pediatric and adult patients with diabetes on MDI or pumps

Refer to the insulin infusion pump user manual to see if Fiasp® can be used. Use in accordance with the insulin pump’s instructions for use.

Fiasp® timing

Dose timing

Fiasp® administration options

Administration options

Fiasp® savings and coverage

Savings and coverage

Taking Fiasp®

For your patients with diabetes who struggle with pre-bolusing mealtime insulin

Choose Fiasp®


Fiasp® is a rapid-acting insulin indicated to improve glycemic control in adult and pediatric patients with diabetes.1

For pediatric and adult patients with diabetes on MDI or pumps

Refer to the insulin infusion pump user manual to see if Fiasp® can be used. Use in accordance with the insulin pump’s instructions for use.

Fiasp® at mealtime

No more waiting to eat

Fiasp® can be taken at the start of a meal or within 20 minutes of starting.1

View dosing options
Fiasp® timing

Rapid onset of appearance

Fiasp® enters the bloodstream in ~2.5 minutes.1

See why Fiasp® is fast
Fiasp® savings and coverage

Familiar formulary coverage

Fiasp® is covered on the majority of plans that cover NovoLog® (insulin aspart) injection 100 U/mL.

Check coverage
Fiasp® (insulin aspart) injection pen, vial, insulin cartridge, and PumpCart®

Choice of administration options for Fiasp®

Fiasp® can be administered using the FlexTouch® pen, the vial and a syringe, the vial and an insulin pump, the PenFill® cartridge and a durable pen, and PumpCart® for use with compatible pump. Which will you choose for your patients?

See how to administer Fiasp®

Refer to the insulin infusion pump user manual to see if Fiasp® can be used. Use in accordance with the insulin pump's instructions for use. 

Fiasp® (insulin aspart) injection pen, vial, insulin cartridge, and PumpCart®

Select Novo Nordisk samples are available

Click here

Indications and Usage for Fiasp® (insulin aspart) injection 100 U/mL

Fiasp® (insulin aspart) injection 100 U/mL is a rapid-acting insulin analog indicated to improve glycemic control in adult and pediatric patients with diabetes mellitus.

Important Safety Information

Contraindications

  • Fiasp® is contraindicated during episodes of hypoglycemia and in patients hypersensitive to Fiasp® or one of its excipients.

Warnings and Precautions

  • Never share a Fiasp® FlexTouch® Pen, PenFill® cartridge or PenFill® cartridge device between patients, even if the needle is changed. Patients using Fiasp® vials must never share needles or syringes with another person. Sharing poses a risk for transmission of blood-borne pathogens.
  • Hyperglycemia or Hypoglycemia with Changes in Insulin Regimen: Changes in an insulin regimen (e.g., insulin strength, manufacturer, type, injection site or method of administration) may affect glycemic control and predispose to hypoglycemia or hyperglycemia. Repeated insulin injections into areas of lipodystrophy or localized cutaneous amyloidosis have been reported to result in hyperglycemia; and a sudden change in the injection site (to an unaffected area) has been reported to result in hypoglycemia. Make any changes to a patient’s insulin regimen under close medical supervision with increased frequency of blood glucose monitoring. Advise patients who have repeatedly injected into areas of lipodystrophy or localized cutaneous amyloidosis to change the injection site to unaffected areas and closely monitor for hypoglycemia. Adjustments in concomitant anti-diabetic treatment may be needed.
  • Hypoglycemia is the most common adverse reaction of insulin, including Fiasp®, and may be life-threatening. Increase glucose monitoring with changes to: insulin dosage, co-administered glucose lowering medications, meal pattern, physical activity; and in patients with renal impairment or hepatic impairment or hypoglycemia unawareness.
  • To avoid medication errors and accidental mix-ups between Fiasp® and other insulin products, instruct patients to always check the insulin label before injection.
  • As with all insulins, Fiasp® use can lead to life-threatening hypokalemia, which then may cause respiratory paralysis, ventricular arrhythmia, and death. Monitor potassium levels in patients at risk for hypokalemia and treat if indicated.
  • Severe, life-threatening, generalized allergy, including anaphylaxis, may occur with insulin products, including Fiasp®.
  • Fluid retention and heart failure can occur with concomitant use of thiazolidinediones (TZDs), which are PPAR-gamma agonists, and insulin, including Fiasp®. Patients should be observed for signs and symptoms of heart failure. If heart failure occurs, dosage reduction or discontinuation of the TZD must be considered.
  • Pump or infusion set malfunctions can lead to a rapid onset of hyperglycemia and ketoacidosis. Prompt identification and correction of the cause of hyperglycemia or ketosis is necessary. Interim therapy with subcutaneous injection of Fiasp® may be required. Patients using continuous subcutaneous insulin infusion pump therapy must be trained to administer insulin by injection and have alternate insulin therapy available in case of pump failure.

Drug Interactions

  • Drugs That May Increase the Risk of Hypoglycemia: Antidiabetic agents, ACE inhibitors, angiotensin II receptor blocking agents, disopyramide, fibrates, fluoxetine, monoamine oxidase inhibitors, pentoxifylline, pramlintide, salicylates, somatostatin analogs (e.g., octreotide), and sulfonamide antibiotics. Dose reductions and increased frequency of glucose monitoring may be required.
  • Drugs That May Decrease the Blood Glucose Lowering Effect of Fiasp®: Atypical antipsychotics (e.g., olanzapine and clozapine), corticosteroids, danazol, diuretics, estrogens, glucagon, isoniazid, niacin, oral contraceptives, phenothiazines, progestogens (e.g., in oral contraceptives), protease inhibitors, somatropin, sympathomimetic agents (e.g., albuterol, epinephrine, terbutaline), and thyroid hormones. Dose increases and increased frequency of glucose monitoring may be required.
  • Drugs That May Increase or Decrease the Blood Glucose Lowering Effect of Fiasp®: Alcohol, beta-blockers, clonidine, and lithium salts. Pentamidine may cause hypoglycemia, which may sometimes be followed by hyperglycemia. Dose adjustment and increased frequency of glucose monitoring may be required.
  • Drugs That May Blunt Signs and Symptoms of Hypoglycemia: Beta-blockers, clonidine, guanethidine, and reserpine. Increased frequency of glucose monitoring may be required 

Adverse Reactions

  • Adverse reactions observed with Fiasp® include hypoglycemia, allergic reactions, hypersensitivity, injection site reactions, lipodystrophy, and weight gain.

Use in Specific Populations

  • Pediatric patients with type 1 diabetes treated with mealtime and postmeal Fiasp® reported a higher rate of blood glucose confirmed hypoglycemic episodes compared to patients treated with NovoLog® (insulin aspart) injection; the imbalance was greater during the nocturnal period. Monitor blood glucose levels closely in pediatric patients.
  • Like all insulins, Fiasp® requirements may be reduced in patients with renal impairment or hepatic impairment. These patients may require more frequent blood glucose monitoring and dose adjustments.

Please click here for Fiasp® Prescribing Information.

Indications and Usage for NovoLog® (insulin aspart) injection 100 U/mL

NovoLog® (insulin aspart) injection 100 U/mL is an insulin analog indicated to improve glycemic control in adults and pediatric patients with diabetes mellitus.

Important Safety Information

Contraindications

  • NovoLog® is contraindicated during episodes of hypoglycemia and in patients hypersensitive to NovoLog® or one of its excipients.

Warnings and Precautions

  • Never Share a NovoLog® FlexPen, NovoLog® FlexTouch®, PenFill® Cartridge, or PenFill® Cartridge Device Between Patients, even if the needle is changed. Patients using NovoLog® vials must never share needles or syringes with another person. Sharing poses a risk for transmission of blood-borne pathogens.
  • Hyperglycemia or Hypoglycemia with Changes in Insulin Regimen: Changes in an insulin regimen (e.g., insulin strength, manufacturer, type, or injection site or method of administration) may affect glycemic control and predispose to hypoglycemia or hyperglycemia. Repeated insulin injections into areas of lipodystrophy or localized cutaneous amyloidosis have been reported to result in hyperglycemia; and a sudden change in the injection site (to an unaffected area) has been reported to result in hypoglycemia. Make any changes to a patient’s insulin regimen under close medical supervision with increased frequency of blood glucose monitoring. Advise patients who have repeatedly injected into areas of lipodystrophy or localized cutaneous amyloidosis to change the injection site to unaffected areas and closely monitor for hypoglycemia. Adjustments in concomitant anti-diabetic treatment may be needed.
  • Hypoglycemia: Hypoglycemia is the most common adverse effect of all insulins, including NovoLog®. Severe hypoglycemia can cause seizures, may lead to unconsciousness, may be life threatening or cause death. Hypoglycemia can impair concentration ability and reaction time; this may place an individual and others at risk in situations where these abilities are important (e.g., driving or operating other machinery). Hypoglycemia can happen suddenly and symptoms may differ in each individual and change over time in the same individual. Symptomatic awareness of hypoglycemia may be less pronounced in patients with longstanding diabetes in patients with diabetic nerve disease, in patients using medications that block the sympathetic nervous system (e.g., beta-blockers), or in patients who experience recurrent hypoglycemia.
  • Risk Factors for Hypoglycemia: The risk of hypoglycemia after an injection is related to the duration of action of the insulin and, in general, is highest when the glucose lowering effect of the insulin is maximal. As with all insulins, the glucose lowering effect time course of NovoLog® may vary in different individuals or at different times in the same individual and depends on many conditions, including the area of injection as well as the injection site blood supply and temperature. Other factors which may increase the risk of hypoglycemia include changes in meal pattern, changes in level of physical activity, or changes to co-administered medication. Patients with renal or hepatic impairment may be at higher risk of hypoglycemia. Patients and caregivers must be educated to recognize and manage hypoglycemia.
  • Hypoglycemia Due to Medication Errors: To avoid medication errors and accidental mix-ups between NovoLog® and other insulin products, instruct patients to always check the insulin label before injection.
  • Hypersensitivity Reactions: Severe, life-threatening, generalized allergy, including anaphylaxis, may occur with insulin products, including NovoLog®.
  • Hypokalemia: All insulins, including NovoLog®, can cause a shift in potassium from the extracellular to intracellular space, possibly leading to hypokalemia. Untreated hypokalemia may cause respiratory paralysis, ventricular arrhythmia, and death. Monitor potassium levels in patients at risk for hypokalemia if indicated (e.g., patients using potassium-lowering medications, patients taking medications sensitive to serum potassium concentration).
  • Fluid Retention and Heart Failure with Concomitant Use of PPAR-gamma Agonists: Fluid retention and heart failure can occur with concomitant use of thiazolidinediones (TZDs), which are PPAR-gamma agonists, and insulin, including NovoLog®. Patients should be observed for signs and symptoms of heart failure. If heart failure occurs, dosage reduction or discontinuation of the TZD must be considered.
  • Hyperglycemia and Ketoacidosis Due to Insulin Pump Device Malfunction: Malfunction of the insulin pump or insulin infusion set or insulin degradation can rapidly lead to hyperglycemia and ketoacidosis. Patients using insulin infusion pump therapy must be trained to administer insulin by injection and have alternate insulin therapy available in case of pump failure.

NovoLog® continuous subcutaneous infusion route (insulin pump): Do not mix NovoLog® with any other insulin or diluent.

Adverse Reactions

  • Adverse reactions observed with NovoLog® include hypoglycemia, allergic reactions, local injection site reactions, lipodystrophy, rash, and pruritus.

Drug Interactions

  • Drugs that may increase the risk of hypoglycemia: antidiabetic agents, ACE inhibitors, angiotensin II receptor blocking agents, disopyramide, fibrates, fluoxetine, monoamine oxidase inhibitors, pentoxifylline, pramlintide, salicylates, somatostatin analog (e.g., octreotide), and sulfonamide antibiotics.
  • Drugs that may decrease the blood glucose lowering effect: atypical antipsychotics, corticosteroids, danazol, diuretics, estrogens, glucagon, isoniazid, niacin, oral contraceptives, phenothiazines, progestogens (e.g., in oral contraceptives), protease inhibitors, somatropin, sympathomimetic agents (e.g., albuterol, epinephrine, terbutaline), and thyroid hormones.
  • Drugs that may increase or decrease the blood glucose lowering effect: alcohol, beta-blockers, clonidine, lithium salts, and pentamidine.
  • Drugs that may blunt the signs and symptoms of hypoglycemia: beta-blockers, clonidine, guanethidine, and reserpine.

Please click here for NovoLog® Prescribing Information.

Reference:

  1. Fiasp [package insert]. Plainsboro, NJ: Novo Nordisk Inc; June 2023.
Diabetes
Other Therapy Areas
Explore diabetes
Explore obesity
Explore growth-related disorders
Explore rare bleeding disorders
Explore rare renal disorders
Explore hormone replacement therapy
  • Diabetes Home
  • Product Information
    Products
    • Diabetes Treatments
    Professional Resources
    • Product Resources Library
      Insulin & Type 1 Diabetes
  • Sample Requests
  • Professional Education
    Diabetes Education
    • Clinical Education Library
      Diabetes Risk Assessment Tool
    Treatment Guidelines
    • ADA Standards of Care
      AACE Diabetes Guidelines
    Additional Resources
    • Organizations & Conferences
  • Patient Support
    Product Education
    • Product Education Materials
    Disease Education
    • Disease Education Library
    Prescription Savings & Coverage
    • Savings Cards
      Insurance Coverage
      Affordability Resources
      ICD-10 Codes for Diabetes
    Support Program
    • Diabetes Management

iLet Bionic Pancreas is a registered trademark of Beta Bionics, Inc, and is used with permission.

Fiasp®, FlexPen®, FlexTouch®, NovoCare®, NovoLog®, and PenFill® are registered trademarks and novoMEDLINK™ is a trademark of Novo Nordisk A/S.

Novo Nordisk is a registered trademark of Novo Nordisk A/S.

All other trademarks, registered or unregistered, are the property of their respective owners.

Non-US Health Care Professionals, please go to www.novonordiskpro.com.

Terms of Use | Privacy Notice | Consumer Health Privacy Notice | Cookie Notice | Privacy Request | Contact Us |
novonordisk-us.com    
© 2023 Novo Nordisk All rights reserved. US23FSP00053 December 2023

Quick links

Request medication samples

Diabetes treatment guidelines

Patient savings card offer

Patient support program